Environmental Indicators
| |
Item |
Environmental Conditions |
| 1 |
Quality Level |
(Ⓙ) & (G) |
| II |
IV |
| 2 |
Temperature Range |
(℃) |
-55 ~ 85 |
| 3 |
Relative Humidity |
(40±2)℃,90% ~ 95% |
| 4 |
Barometric Depression |
(k Pa) |
100 ~ 0.266 |
| 5 |
Sinusoidal Vibration |
(Hz) |
10 ~ 2000 |
| (m/s2) |
147 |
196 |
| 6 |
Shock |
(m/s2) |
490 |
735 |
| 7 |
Acceleration |
(m/s2) |
490 |
735 |
Technical Indicators
| Contact Arrangement |
6 groups conversion |
Operate Time(ms) |
≤10 |
| Coil Power(W) |
3.56 |
Release Time(ms) |
≤10 |
| Leakage rate(Pa.cm3/s) |
≤1×10-2 |
Contact Load |
28Vd.c.,
5A (Resistive) |
| Contact Resistance(Ω) |
Before Life |
≤0.05 |
| After Life |
≤0.1 |
Contact Life |
5×104 cycles |
| Insulation Resistance(MΩ) |
Normal temperature and humidity |
≥500(500Vd.c.) |
| High temperature and humidity |
≥10(500Vd.c.) |
Overload |
Resistive 28Vd.c., 20A,50 cycles |
| Dielectric Strength Vr.m.s.(50Hz) |
Normal conditions |
≥500 |
Weight(g) |
40±4 |
| Barometric Depression |
≥250 |
Coil Characteristics
| Coil voltage Vd.c. |
20℃ |
Temperature range |
| Coil resistance (1±10%)Ω |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
| 28 |
220 |
18 |
2 |
24 |
1 |
Mounting Type
Click to Enlarge
Curves for DC Voltages above Normal Rating: Resistive Load Only
Circuit ( View From Bottom )
|