Home >> Products >> Relay >> Electromagnetic Relay >> Non-Magnetic Latching Relay >> ≤10A >> 6JR-3
|
|
6JR-3
|
It is our standard, small electromagnetic relay. Various technical indicators are in line with our general specifications. The specifications are of large margin, high reliability. Over a long period of production, it can be used for supporting test and operate in harsh environment. Mainly used in signal transmission and the circuit switching of automatic control system in high reliable division.
|
|
Environmental Indicators
| |
Project Name |
Environmental Conditions |
| 1 |
Quality Rating |
(Ⓙ) & (G) |
G+ |
GJB[J] |
KJ |
| III |
| 2 |
Ambient temperature |
(℃) |
-55~85 |
-65~105 |
| 3 |
Relative Humidity |
(40±2) ℃,90%~95% |
| 4 |
Barometric Depression |
(kPa) |
0.67~0.27 |
4.39 |
| 5 |
Sinusoidal Vibration |
(Hz) |
10~2000 |
| (m/s2) |
147 |
196 |
| 6 |
Random Vibration |
(m/s2)2/Hz |
10 |
25 |
| 7 |
Impact |
(m/s2) |
735 |
735 |
| 8 |
Acceleration |
(m/s2) |
735 |
735 |
Technical Indicators
| Contact Type |
6 group conversion |
Operate Time(ms) |
≤10 |
| Coil power consumption(W) |
1.4 |
Release Time(ms) |
≤5 |
| Leakage rate(Pa.cm3/s) |
≤1×10-2 |
Contact Load |
28Vd.c.,
2A (Resistive) |
10mV~50mV10μA~50μA (Lowlevel) |
| Contact Resistance(Ω) |
Before Experiment |
≤0.05 |
| After Experiment |
≤0.1 |
Lifetime (times) |
1×105 |
1×105 |
| Insulation Resistance(MΩ) |
Normal temperature and humidity |
≥10000(100Vd.c.) |
| High temperature and normal humidity |
≥100(100Vd.c.) |
Overload |
Resistive 28Vd.c.,
4A,100times |
| Dielectric Strength Vr.m.s.(50Hz) |
Normal conditions |
≥500 |
Failure Rate |
L |
| Barometric Depression |
≥350 |
Quality(g) |
≤32 |
Coil Characteristics(Mainly for KJ)
| Coil voltage |
25℃ |
Temperature range |
| Rating Vd.c. |
Coil resistance (1±10%)Ω |
Action voltage Maximum Vd.c. |
Release voltage Minimum Vd.c. |
Action voltage Maximum Vd.c. |
Release voltage Minimum Vd.c. |
| 24 |
270 |
15 |
2 |
18 |
1.0 |
| 28 |
420 |
18 |
2 |
23 |
1.0 |
| 28 |
560 |
16 |
2 |
23 |
1.0 |
Mounting Type
Click to Enlarge
Curves for DC Voltages above Normal Rating: Resistive Load Only
Circuit ( View From Bottom )
|