4JL-4
|
This electromagnetic relays can be used for switching transmission signals of electricity and pneumatic equipment.
|
|
Environmental Indicators
| |
Item |
Environmental Conditions |
| 1 |
Quality Level |
(Ⓙ) & (G) |
Aerospace |
| II |
IV |
| 2 |
Temperature Range |
(℃) |
-55~85 |
| 3 |
Relative Humidity |
(40±2) ℃,90%~95% |
| 4 |
Barometric Depression |
(kPa) |
0.67~0.13 |
0.67~0.27 |
| 5 |
Sinusoidal Vibration |
(Hz) |
10~2000 |
| (m/s2) |
147 |
196 |
| 6 |
Random Vibration |
(m/s2)2/Hz |
— |
20 |
| 7 |
Shock |
(m/s2) |
490 |
735 |
980 |
| 8 |
Acceleration |
(m/s2) |
490 |
735 |
Technical Indicators
| Contact Arrangement |
6 PDT |
Operate Time(ms) |
≤15 |
| Coil Power(W) |
0.7 |
Release Time(ms) |
≤5 |
| Leakage rate(Pa.cm3/s) |
≤1×10-3 |
Contact Load |
28Vd.c.,
3A (Resistive) |
10mV~50mV10μA~50μA (Lowlevel) |
| Contact Resistance(Ω) |
Before Life |
≤0.05 |
| After Life |
≤0.1 |
Contact Life |
1×104 cycles |
1×105 cycles |
| Insulation Resistance(MΩ) |
Normal temperature and humidity |
≥500(500Vd.c.) |
| High temperature and humidity |
≥10(500Vd.c.) |
Overload |
Resistive 28Vd.c., 6A,100 cycles |
| Dielectric Strength Vr.m.s.(50Hz) |
Normal conditions |
≥500 |
Failure Rate |
M |
| Barometric Depression |
≥250 |
Weight(g) |
≤32 |
Coil Characteristics(Mainly for KJ)
| Coil voltage Vd.c. |
20℃ |
Temperature range |
| Coil resistance (1±10%)Ω |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
| 20 |
570 |
13 |
1.4 |
17 |
0.7 |
| 28 |
1000 |
18 |
2 |
24 |
1 |
Mounting Type
Click to Enlarge
Curves for DC Voltages above Normal Rating: Resistive Load Only
Circuit ( View From Bottom )
|