4JG-4A
|
This is an electromagnetic relay of middle-power. Various technical indicators are in line with our general specifications. Applicable to all types of aircraft control circuits, power distribution systems.
|
|
Environmental Indicators
| |
Item |
Environmental Conditions |
| 1 |
Quality Level |
(Ⓙ) & (G) |
GJB[J] |
KJ |
| II |
IV |
| 2 |
Temperature Range |
(℃) |
-55~85 |
-65~105 |
| 3 |
Relative Humidity |
(40±2)
℃,90%~95% |
| 4 |
Barometric Depression |
(kPa) |
0.67~0.27 |
4.39 |
| 5 |
Sinusoidal Vibration |
(Hz) |
10~2000 |
| (m/s2) |
147 |
196 |
| 6 |
Random Vibration |
(m/s2)2/Hz |
- |
20 |
| 7 |
Shock |
(m/s2) |
490 |
735 |
| 8 |
Acceleration |
(m/s2) |
490 |
735 |
Technical Indicators(Mainly for J, KJ)
| Contact Arrangement |
4 PDT |
Operate Time(ms) |
≤20 |
| Coil Power(W) |
2.9 |
Release Time(ms) |
≤10 |
| Leakage rate(Pa.cm3/s) |
≤1×10-2 |
Contact Load |
28Vd.c.,
20A Or 50Vd.c.,
10A (Resistive) |
10mV~50mV10μA~50μA (Lowlevel) |
| Contact Resistance(Ω) |
Before Life |
≤0.02 |
| After Life |
≤0.05 |
Contact Life |
5×103 cycles or 5×104 cycles |
4×105 cycles |
| Insulation Resistance(MΩ) |
Normal temperature and humidity |
≥10000(100Vd.c.) |
Overload |
Resistive 28Vd.c., 40A,100 cycles |
| High temperature and humidity |
≥100(100Vd.c.) |
| Dielectric Strength Vr.m.s.(50Hz) |
Normal conditions |
≥500 |
Failure Rate |
L |
| Barometric Depression |
≥350 |
Weight(g) |
≤105 |
Coil Characteristics
| Coil voltage Vd.c. |
20℃ |
Temperature range |
| Coil resistance (1±10%)Ω |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
| 15 |
70 |
9.5 |
1.2 |
12.5 |
0.5 |
| 28 |
270 |
18 |
2.0 |
24 |
1.0 |
Mounting Type
Click to Enlarge
Curves for DC Voltages above Normal Rating: Resistive Load Only
Circuit ( View From Bottom )
|