Home >> Products >> Relay >> Electromagnetic Relay >> Non-Magnetic Latching Relay >> >10A >> 2JT60-3
|
|
2JT60-3
|
Small size, light weight, switching power. It can be used in automatic control system of high reliable division.
|
|
Environmental Indicators
| |
Item |
Environmental Conditions |
| 1 |
Quality Level |
(Ⓙ) & (G) |
| II |
— |
| 2 |
Temperature Range |
(℃) |
-55~85 |
| 3 |
Relative Humidity |
(40±2) ℃,90%~95% |
| 4 |
Barometric Depression |
(kPa) |
4.39 |
| 5 |
Sinusoidal Vibration |
(Hz) |
10~2000 |
| (m/s2) |
147 |
| 6 |
Random Vibration |
(m/s2)2/Hz |
10 |
20 |
| 7 |
Shock |
(m/s2) |
490 |
| 8 |
Acceleration |
(m/s2) |
490 |
Technical Indicators
| Contact Arrangement |
Main:2 group normally open Auxiliary:1 PDT |
Operate Time(ms) |
≤30 |
| Coil Power(W) |
3.4 |
Release Time(ms) |
≤15 |
| Leakage rate(Pa.cm3/s) |
≤1×10-2 |
Contact Load |
Main contact:28Vd.c.,
60A(Resistive) Auxiliary contact:28Vd.c.,
1A(Resistive) |
| Contact Resistance(Ω) |
Before Life |
Main:≤0.003 Auxiliary:≤0.02 |
| After Life |
Main:≤0.008 Auxiliary:≤0.1 |
Contact Life |
5×103 cycles |
| Insulation Resistance(MΩ) |
Normal temperature and humidity |
≥10000(100Vd.c.) |
| High temperature and humidity |
≥100(100Vd.c.) |
Overload |
Resistive 28Vd.c., 80A,50 cycles |
| Dielectric Strength Vr.m.s.(50Hz) |
Normal conditions |
≥500 |
Weight(g) |
≤200 |
| Barometric Depression |
≥200 |
Coil Characteristics
| Coil voltage Vd.c. |
20℃ |
Temperature range |
| Coil resistance (1±10%)Ω |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
| 28 |
230 |
18 |
2 |
24 |
1 |
Mounting Type
Click to Enlarge
Curves for DC Voltages above Normal Rating: Resistive Load Only
Circuit ( View From Bottom )
|