Home >> Products >> Relay >> Electromagnetic Relay >> Non-Magnetic Latching Relay >> ≤10A >> 10JT10-1
|
|
10JT10-1
|
Small size, light weight, switching power, rich of PDT, the product technical indicators close to the international advanced level, which is leading in domestic. It can be used in automatic control system of high reliable division.
|
|
Environmental Indicators
| |
Item |
Environmental Conditions |
| 1 |
Quality Level |
(Ⓙ) & (G) |
| I |
| 2 |
Temperature Range |
(℃) |
-55 ~ 85 |
| 3 |
Relative Humidity |
(40±2)℃,90% ~ 95% |
| 4 |
Barometric Depression |
(kPa) |
0.266 |
| 5 |
Sinusoidal
Vibration |
(Hz) |
10 ~ 500 |
| (m/s2) |
98 |
| 6 |
Shock |
(m/s2) |
294 |
Technical Indicators
| Contact Arrangement |
5 groups normally open 5 groups normally closed |
Dielectric Strength Vr.m.s.(50Hz) |
Normal conditions |
≥500 |
| Coil Power(W) |
3.4 |
Barometric Depression |
≥250 |
| Leakage rate(Pa.cm3/s) |
≤5×10-1 |
Contact Load |
28Vd.c.,
10A (Resistive) |
| Contact Resistance(Ω) |
Before Life |
≤0.05 |
Contact Life |
1×104 cycles |
| After Life |
≤0.1 |
| Insulation Resistance(MΩ) |
Normal temperature and humidity |
≥100(500Vd.c.) |
Weight(g) |
≤230 |
| High temperature and humidity |
≥10(500Vd.c.) |
Coil Characteristics
| Coil voltage Vd.c. |
25℃ |
Temperature range |
| Coil resistance (1±10%)Ω |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
Pick-up voltageMaximum Vd.c. |
Drop-out voltageMinimum Vd.c. |
| 26 |
198 |
18 |
2 |
22 |
1 |
Mounting Type
Click to Enlarge
Curves for DC Voltages above Normal Rating: Resistive Load Only
Circuit ( View From Bottom )
|